IES multi-method non-destructive testing station with ultrasonic detector, magnetic yoke, borescope and contained penetrant area
NDT01Made to order

Multi-Method NDT Inspection Station

A contained multi-method station for ultrasonic, magnetic-particle, penetrant and visual inspection practice.

Discipline
Inspection and materials engineering
Recommended level
Levels 3–6
Application
Ultrasonic testing · Surface inspection · Quality assurance
Base system from£18,500 excl. VAT
Typical configured system£24,000–£36,000 excl. VAT
The base system is a usable teaching product. Select only the extra capability your curriculum and site require.Typical lead time: 16–24 weeksDelivery, site services and final manufacturing dates are confirmed with the formal quotation.
Request a quotation
Manufactured only when ordered

IES does not hold this product as finished stock. Manufacture begins after the order is accepted and the configuration is signed off. The stated lead time runs from that point and is confirmed in the formal quotation.

Commercial information

What to expect when ordering

Availability
Made to order
Manufacturing lead time
16–24 weeks, starting after order acceptance and specification sign-off
Published pricing
Budget prices exclude VAT. The formal quotation confirms the selected configuration and final price.
Delivery and installation
Quoted separately where transport, positioning, utilities, specialist installation or commissioning are required.

Build the right system

Optional extras

The base price includes the working core system, standard controls and guarding, a core practical-teaching pack and pre-dispatch functional testing. These options let a college add capability without paying for it as standard.

Eddy-current inspection module

From £4,500 excl. VAT

Adds an eddy-current instrument, probes, reference standards and a dedicated practical resource pack.

Connected data pack

From £1,850 excl. VAT

Adds the relevant data acquisition, interface or export capability for deeper analysis and evidence capture.

Additional curriculum route

£750 per route excl. VAT

A further qualification-mapped activity set, lecturer guide and assessment evidence pack.

On-site commissioning and staff training

From £1,250 + travel excl. VAT

Installation checks, operational handover and practical familiarisation for teaching and technical staff.

Three-year support plan

From £1,450 excl. VAT

Scheduled technical review, priority remote support and an annual resource-update entitlement.

Delivery, specialist lifting, utilities, building work, third-party licences and installation are quoted separately where required.

Included in the base system

A complete teaching product, not an empty frame.

  • The complete working core equipment described in the product overview and technical specification
  • Standard operating controls, protective devices and guarding appropriate to the agreed design
  • The core learner activities, lecturer guidance and assessment materials listed on this page
  • Assembly, pre-dispatch inspection and functional acceptance testing
  • Operating documentation and a remote handover session

College preparation

Likely site requirements

  • A suitable teaching or workshop location with the operating space and safe clearances agreed in the final specification
  • A suitable electrical supply and local isolation arrangement; voltage, current and connector requirements are confirmed before manufacture
  • Safe delivery access, door widths and any lifting or positioning requirements confirmed before dispatch
  • A college computer or network connection where digital software, data export or online resources are selected
  • Workshop-floor capacity and delivery access suitable for a mobile or floor-standing engineered system
  • Local exhaust connection, controlled chemical storage and disposal arrangements for the selected penetrant and magnetic-particle consumables
These are planning requirements. The final utility, space, access and safety requirements are confirmed for the ordered configuration before manufacture.

Made-to-order process

From teaching need to working system.

  1. Discuss the requirementCurriculum, learner numbers, intended practical work and available space.
  2. Agree the configurationCore system, optional modules, resources, site requirements and responsibilities.
  3. Accept the quotationThe specification, price, payment schedule and confirmed lead time form the order.
  4. Manufacture the systemIES or an approved manufacturing partner builds the ordered configuration.
  5. Inspect and testPre-dispatch functional acceptance checks are completed and recorded.
  6. Deliver and commissionThe agreed delivery, installation, handover and staff training are completed.

Product overview

The NDT01 combines an ultrasonic flaw detector and reference blocks, magnetic-particle yoke, contained dye-penetrant area, borescope and representative flawed specimens. It develops practical inspection judgement and evidence recording without using ionising radiation.

Technical features

  • Ultrasonic flaw detector, probes and calibration blocks
  • Magnetic-particle yoke and controlled demonstration area
  • Contained penetrant-inspection booth with local extraction connection
  • Borescope, visual aids and traceable reference specimens

Learning applications

  • Select an appropriate non-destructive inspection method
  • Calibrate equipment and follow a written procedure
  • Locate, characterise and record representative indications
  • Evaluate limitations and produce a structured inspection report

Qualification context

  • Engineering inspection, welding, aerospace, marine and mechanical programmes
  • EAL, City & Guilds and higher technical materials or quality study
  • Supports underpinning education and practice only; it is not PCN certification or BINDT-approved training

Digital integration

  • Digital inspection reports and image records
  • Reference-indication, calibration and evaluation datasets

Included teaching resources

  • Multi-method NDT learner workbook
  • Procedure and reference-specimen pack
  • Lecturer chemical-control and setup guide
  • Inspection assessments and interpretation guide

Curriculum mapping requires confirmation.

Qualification references describe potential teaching relevance, not awarding-organisation endorsement or automatic compliance with a current specification. Educators should verify the applicable specification, centre arrangements and local risk controls.

Quotation request · NDT01

Configure this system for your learners.

Share the intended application, approximate quantity and procurement timescale. IES will review your requirements and contact you to agree the configuration and prepare a formal quotation.

Submitting this form requests a product discussion and quotation. No payment is taken and an order is only created after a formal quotation is accepted.