INSTITUTE OF ENGINEERING SKILLS / VIRTUAL ENGINEERING LABORATORIES / V1.1

Learner workbook & calculation worksheets

Electrical Fault-Finding Laboratory • 24 V DC • 8 November 2026

Name: __________________________ Group: __________________ Date: ______________

Working method

Predict, set up, measure, interpret and justify. Write units. Record the supply, S1 and J1 state with each set of measurements. Use a voltage measurement to establish isolation in the simulated circuit before selecting Ω. The simulator adds conservative blocking while the supply is enabled.

Formulae: V = IR; P = VI = I²R = V²/R; Rseries = R1 + R2; 1/Rparallel = 1/R1 + 1/R2.

01 / Establish a healthy circuit

Investigation objective

Establish the healthy circuit baseline and explain how voltage is shared by series loads.

Relevant theory

V = IR. Voltage is a difference between two points. In the load branch, R1 and R2 share the branch voltage; the relay and lamp form additional parallel paths.

Equipment preparation

  1. Start with power isolated, S1 closed and J1 closed.
  2. Select DC voltage, the V/Ω socket and black probe at 0.
  3. Identify PS, L and X in both views before energising.

Learner prediction

Predict the supply voltage, the R2 voltage and the ideal series-branch current. Explain your reasoning before measuring.

Required measurements

  1. PS to 0: establish the supply.
  2. L to 0: measure the voltage available to the load branch.
  3. X to 0: measure R2 voltage.
  4. L to X: measure the drop across R1.

Recorded evidence

Function / socketRed / blackPredictionReading + unitInterpretation

Supply / switch / link states: ___________________________________________

Interpretation questions

  1. Do the R1 and R2 voltage drops add to the load-branch voltage?
  2. Why is the measured current slightly below the ideal 24 / 220 A prediction?
  3. What additional loads draw current from the source?

Calculation

Ignoring wiring resistance and other branches, what is 24 V / (100 Ω + 120 Ω) in mA?

Conclusion and completion feedback

Explain the supporting evidence and identify model limitations. Record lecturer feedback or the formative calculation outcome.

02 / Measure current in series

Investigation objective

Insert an ammeter in series and distinguish branch current from total source current.

Relevant theory

An ammeter introduces a small shunt resistance. A voltmeter is connected in parallel and has high input resistance. The red lead socket is part of the electrical connection.

Equipment preparation

  1. Isolate the power supply before opening J1.
  2. Select DC current and move the red lead to the A socket.
  3. Connect red to S and black to L across the opened J1 link.

Learner prediction

Predict the sign and approximate magnitude of branch current, and explain the effect of the 0.1 Ω meter shunt.

Required measurements

  1. S to L in DC current with J1 open and power enabled.
  2. L to S in DC current: compare polarity.
  3. Isolate power before reconnecting J1 and changing sockets.
  4. In voltage mode at V/Ω, measure X to 0 and compare I = V / 120 Ω.

Recorded evidence

Function / socketRed / blackPredictionReading + unitInterpretation

Supply / switch / link states: ___________________________________________

Interpretation questions

  1. Why must J1 be open for a series current measurement?
  2. How does shunt resistance affect the reading?
  3. Why does the source carry more current than the R2 branch?

Calculation

What power would a 120 Ω load dissipate at exactly 0.10 A?

Conclusion and completion feedback

Explain the supporting evidence and identify model limitations. Record lecturer feedback or the formative calculation outcome.

03 / Locate an open circuit

Investigation objective

Locate an interruption using voltage differences, then explain the isolated resistance path.

Relevant theory

An open series path stops current. A voltage measurement across the interruption can approach supply voltage while a resistance test gives OL if no alternative path exists.

Equipment preparation

  1. Start with power isolated, S1 and J1 mechanically closed. The activity contains an internal J1 fault.
  2. Select DC voltage and the V/Ω socket.
  3. Use node labels to distinguish S before the link and L after it.

Learner prediction

Predict current in the interrupted load branch, voltage across the interruption and whether another resistance path might exist.

Required measurements

  1. With power enabled: S to 0, L to 0 and S to L.
  2. Isolate power and open S1 before selecting resistance.
  3. Measure S to L and explain the route through the coil and load resistors.

Recorded evidence

Function / socketRed / blackPredictionReading + unitInterpretation

Supply / switch / link states: ___________________________________________

Interpretation questions

  1. What evidence locates the interruption at J1?
  2. Why can H1 stay lit when the R2 branch is interrupted?
  3. Why can an open link measure a finite in-circuit resistance?

Calculation

What current flows through an ideal open series path?

Conclusion and completion feedback

Explain the supporting evidence and identify model limitations. Record lecturer feedback or the formative calculation outcome.

04 / Find unwanted resistance

Investigation objective

Find excessive series resistance by comparing voltage drops under load.

Relevant theory

An unwanted resistance in a loaded path creates a voltage drop. The R1 fault adds 900 Ω to its nominal 100 Ω. With the supply off, in-circuit resistance includes parallel paths.

Equipment preparation

  1. Start isolated, with S1 and J1 closed.
  2. Select DC voltage and the V/Ω socket.
  3. Locate L, X and 0, and identify the nominal R1 and R2 values.

Learner prediction

Predict which resistor section takes most of the supply voltage when R1 increases to 1000 Ω, and estimate R2 voltage.

Required measurements

  1. With power enabled: L to X, X to 0 and L to 0.
  2. Compare R1 and R2 drops with the healthy baseline.
  3. Isolate power and measure L to X in resistance mode; account for parallel paths.

Recorded evidence

Function / socketRed / blackPredictionReading + unitInterpretation

Supply / switch / link states: ___________________________________________

Interpretation questions

  1. Which voltage drop supports the high-resistance diagnosis?
  2. Why is a loaded voltage-drop test useful?
  3. Why might the in-circuit Ω reading differ from the isolated component value?

Calculation

For an ideal 24 V supply across 1000 Ω + 120 Ω, calculate the 120 Ω load voltage.

Conclusion and completion feedback

Explain the supporting evidence and identify model limitations. Record lecturer feedback or the formative calculation outcome.

05 / Relay control and protected shorts

Investigation objective

Distinguish coil and indicator faults and explain the response of latching protection.

Relevant theory

The relay coil and contact are separate parts. The contact closes above 18 V coil pickup and releases below 8 V. An open coil cannot actuate the contact. Q1 is a simplified instantaneous latching 0.50 A cut-out.

Equipment preparation

  1. Start isolated with S1 and J1 closed.
  2. Select DC voltage and V/Ω.
  3. Identify the separate K1 coil and K1 normally open contact.

Learner prediction

Predict the contact and lamp state if the coil is open, even when its supply node has voltage.

Required measurements

  1. With power enabled: P to 0, S to 0 and K to 0.
  2. Isolate power, open S1 and J1, then measure S to 0 in resistance mode.
  3. After completing this practical, use Explore to compare a bus short: isolate, choose the short, close S1/J1 and energise.
  4. Observe Q1 latch, then isolate, remove the fault, reset protection and retest.

Recorded evidence

Function / socketRed / blackPredictionReading + unitInterpretation

Supply / switch / link states: ___________________________________________

Interpretation questions

  1. Why does coil-node voltage alone not prove coil current?
  2. What observation distinguishes an open coil from an open lamp?
  3. Why does cycling the power fail to reset a latched Q1?

Calculation

What current does a nominal 1200 Ω relay coil draw at 24 V? Enter mA.

Conclusion and completion feedback

Explain the supporting evidence and identify model limitations. Record lecturer feedback or the formative calculation outcome.

Assessment questions

1. Why must you isolate the supply before using resistance mode?
2. Why can the resistance across an open link be finite?
3. How can a high-resistance connection be identified without dismantling the circuit?
4. What changes when a meter is connected in the A socket across a supply?
5. Why can H1 be dark when the supply and coil-node voltages look normal?
6. What happens if Q1 is reset while the short remains?
7. Does the in-circuit ohmmeter always read the labelled component value?