IES Virtual Engineering Laboratories / Materials

Universal Testing
Machine LaboratoryV2.4

Prepare. Predict. Test. Interpret.

Virtual tensile-testing laboratory · one engineering model, from specimen to evidence.
Laboratory message: Configure the specimen, complete the machine preparation and zero the instruments.

Operator guide

Follow the four stages.

  1. 1Configure specimenComplete
  2. 2Prepare machineCurrent stage
  3. 3Run testNot started
  4. 4Review evidenceNot started
02 / Test station

IES Universal 100

IES / UNIVERSAL 100VIRTUAL ENGINEERING LABORATORYMOVING UPPER CROSSHEADLOAD CELLFIXED LOWER CROSSHEADREADYORIGINAL IES DESIGNDimensional motion · qualitative neck / fracture shape
Load cell0.000 kN
Gauge extension0.000 mm
Crosshead displacement0.000 mm
Engineering stress0.000 MPa
Engineering strain0.000 %
Experiment time0.0 s

READY · elastic · work 0.000 J

Elastic extension 0.000 mm / plastic extension 0.000 mm
Machine controlsWaiting for preparation

Physical test speed: 5 mm/min. Playback changes viewing time only; it does not change the test conditions.

Preparation incomplete · finish 7 items before starting →
Immediately stops motion and latches the machine. Reset is required afterwards.

Virtual frame limits: 100 kN load and 200 mm travel. Physical safety systems are not simulated.

03 / Measurements

Watch the response.

F = σA₀ · ε = ΔL/L₀ · σ = Eε in the elastic region.

Force / extension

03.226.026.44129.6618.112.924.1Gauge extension (mm)Force (kN)
0.000 s · 0.000 mm · 0.000 kN · ε = 0.0000 · elasticClick to measure, or use the point slider and arrow keys. Green shading: linear elastic region. Dashed lines: comparison tests.

Engineering stress / strain

06.4412012.924119.336125.8482Engineering strain (%)Engineering stress (MPa)
0.000 s · 0.000 % · 0.000 MPa · ε = 0.0000 · elasticClick to measure, or use the point slider and arrow keys. Green shading: linear elastic region. Dashed lines: comparison tests.
Current: IES-001
ε = 0.000000 · test progress 0.0%
Preparation workflow

Prepare from top to bottom.

Complete each item in order. Settings lock when a test begins; changing a specimen setting clears affected preparation checks.

7 preparation items remainingNext: Inspect the specimen for visible damage before installation.
  1. Select materialLow-carbon steel
  2. Confirm no visible cracks, damage or misalignment. The virtual specimen is ideal.
  3. Enter measured reduced-section dimensions above; area is calculated from them.
  4. Recommended for this specimen: Wedge or flat-faced grips. You still select and check the grip as a real operator would.
  5. Align the specimen in both grips; avoid bending.
  6. Use L₀ = 50 mm, not the grip separation.
  7. Install specimen and set gauge length first.
  8. 5 mm/min; ideal ambient, rate-independent model.
  9. Useful for guided learning, but it is not required to start the machine.
  10. Begin testUse Start test after preparation.
  11. Review resultsRecord evidence and interpret the curves below.
Return to machine controls ↑

Explore mode

Investigate the engineering.

Determining tensile modulus

Objective

Determine E from two readings within the linear elastic region.

Relevant theory

The elastic slope is E = (σ₂ − σ₁) / (ε₂ − ε₁). Strain is dimensionless; MPa / 1000 gives GPa.

Equipment preparation

Choose steel, rectangular 10 × 5 mm, L₀ = 50 mm. Attach the ideal extensometer. Use the graph Elastic region control and pause early.

Prediction prompt

Which material do you expect to have the steepest elastic gradient?

Measurements

Select two elastic data points. Record force, extension, stress and dimensionless strain for each.

Calculations

Calculate area, both stresses and strains, then the slope in GPa. Avoid using plastic-region points.

Interpretation

How would a crosshead measurement differ from gauge strain on a real machine?

Recorded learner evidence

Teacher explanation / lecturer notes

Worked calculation

For A₀ = 50 mm² and L₀ = 50 mm: at ε = 0.0005, σ = 100 MPa, F = 5000 N, ΔL = 0.025 mm. At ε = 0.001, σ = 200 MPa, F = 10000 N, ΔL = 0.050 mm. E = 100 / 0.0005 = 200000 MPa = 200 GPa.

Lecturer notes

Check that the learner uses dimensionless strain rather than percent. In real testing, machine and grip compliance make crosshead extension unsuitable for accurate modulus without correction. The simulator uses ideal gauge data.

Assess reasoning and units; this is formative evidence, not certification of practical competence.

Five learner questions

  1. How does the initial gradient relate to elastic modulus?
  2. Why is engineering stress based on the original area?
  3. Which material has the greatest elastic stiffness?
  4. What happens to engineering stress after the ultimate strength?
  5. Which specimen property changes force without changing the stress–strain curve?
Formative assessment answers
  1. E is the slope of engineering stress against dimensionless strain in the elastic region.
  2. Original area supplies a consistent nominal reference; true stress is not modelled.
  3. The low-carbon steel preset has the highest assumed elastic modulus.
  4. For the ductile presets it falls in the nominal necking branch; brittle profiles fracture at their peak.
  5. Original cross-sectional area changes force through F = σA₀.

Results & My IES

Keep the evidence.

Results are calculated from the numerical dataset. Material parameters are illustrative assumptions.

Calculated observations · incomplete test
MaterialLow-carbon steel
UK technical referenceBS EN ISO 6892-1:2019
Standards statusReference only: not standards-compliant testing
Specimen IDIES-001
Geometryrectangular
Original area50.000 mm²
Gauge length50 mm
Initial grip separation100 mm
Physical test speed5 mm/min
Maximum force observed0.000 kN
Tensile modulus (elastic slope)Not reached / not applicable
Yield strengthNot reached / not applicable
0.2% proof stressNot reached / not applicable
Peak stress so far (incomplete test)0.000 MPa
Model gauge elongation at fractureNot reached / not applicable
Fracture force (immediately before break)Not reached / not applicable
External work on ideal gauge0.000 J
End stateready
Model / attemptutm-v2.1 / unsaved-attempt

Comparison laboratory

Change one variable.

Up to six tests overlay both live graphs. Area changes force; gauge length changes extension. Geometry does not change the assumed material stress–strain law. Speed changes elapsed time only. Comparisons remain in this tab; use My IES or exports for lasting records.

Complete a test and add it here, then reset and test a new specimen.

Educational model

Use the model critically.

Read material models, assumptions and verification →