IES Universal Testing Machine Laboratory V2: release report

Date: 8 November 2026. Model: `utm-v2.0`. Existing route retained: `/simulations/tensile-test`.

Delivered

Observed verification outcomes

CheckOutcome
Production application build and artifact validationPassed
Full retained regression suite plus new UTM tests75 tests, 75 passed, 0 failed
New pure engineering/reference tests15 passed
New isolated UTM account API integration testPassed, including authenticated ownership, update/reopen and preservation of electrical/resource rows
Independent engineering fixturesRectangular/cylindrical area, elastic steel, yield/UTS/fracture, aluminium offset proof and integrated work agree
Legacy tensile, beam and electrical regressionsPassed in the full suite
Mobile 390×844Completed brittle dog-bone test; 3 GPa, 60 MPa, 1.5 J; comparison overlays passed
Tablet 768×1024Completed aluminium d=8 mm cylinder in flat view; 69 GPa, Rp0.2 202.914 MPa, UTS 310 MPa
Desktop 1440×1000Steel pause/resume, locked settings, independent evidence gate and fracture passed
Classroom 1920×1080Keyboard Enter start and classroom layout completed steel at 217.609 J
Page-wide overflowNone at all four tested frame sizes
Browser CSV downloadCompleted direct-tab download inspected: 402 samples, final force 0 N, pre-break 16500 N, work 217.609375 J
Browser HTML report downloadCompleted direct-tab download inspected: two SVG graphs, recorded 430 MPa UTS and test conditions
General TypeScript checkExisting project-wide issues remain: 17 diagnostic locations/codes, identical on untouched baseline and release source; no new diagnostic location/code

Steel reference conditions: 10×5 mm original section, 50 mm gauge, 5 mm/min. At ε=.001: 200 MPa, 10000 N, .05 mm extension. Full test: maximum force 21.5 kN, UTS 430 MPa, pre-break force 16.5 kN, loaded gauge elongation 25%, external work 217.609375 J.

Reference fixture values were independently hand-calculated and checked using Decimal arithmetic, not exported from the simulation to form the expected answer. Numerical tests verify this authored educational model, not agreement with real material experiments.

Browser scenarios and observed values are retained in `tests/browser/utm-v2.cua.js` and `docs/utm/BROWSER_RESULTS.json`. An iframe download event timed out; both direct-tab downloads then succeeded and their real files were inspected. One offscreen iframe pointer action was recovered with a fresh observation and keyboard Space. Temporary responsive QA wrappers were removed before release packaging.

Preserved compatibility and access

The legacy `tensile-model.ts` is unchanged and its existing test still passes. No migration or new membership tier is required. New results use `utm:<attemptId>` keys and a dedicated owner-scoped API while retaining the established member_activity table and dashboard links. Existing electrical result handling was left unchanged and verified alongside UTM records in isolated D1. No live learner record was modified during QA.

Known limitations

Public ISO 527-1:2019 and ISO 6892-1:2019 scopes were checked; the complete paid standards and full implementation have not been independently validated for compliance. Technical model details, equations, parameter tables and references are in `MODEL_AND_VERIFICATION.md` and the public technical notes.

Release control

The previous published simulator remained in place throughout implementation and QA. Publication uses the original IES project, public audience and URL, only after successful production build, artifact validation, automated regression and relevant browser checks. Hosting deployment outcome is reported by the publishing system; the report does not claim a production-account write or physical experimental validation.

Open the UTM laboratory · Technical model notes · Lecturer guide